AR-4610 Line Push to Lock Plastic Fasteners Installation
- AR-4610 Line studs and receptacles are packed separately.
- The receptacle is easily snapped into a square hole from the
front panel and becomes self-retained.
- The stud is then pushed into the receptacle until it snaps in
place.
- A small plastic mallet may be convenient for stud insertion.
Hole Dimensions |
Panel Hole: |
.360 +.005 (9.14 +.13 mm) square
|
Support Hole: |
.375 +.005 (9.53 +.13 mm) square
|
Hole Misalignment: |
± .020 (±.51 mm)
|
|
|
|