SU-2300 Line Receptacle Installation

Rigid Receptacle

1. Drill holes and countersink rivet holes

Drill and Countersink Panel Drawing
Stud Type "A"
±.010
"K"
±.005
J Drill Size Countersink Rivet
2351-20, 2351-W20, 2356-20 .468" .750" .096" #41
(.096")
3/16 D x 110° 3/32"
2501-20, 2501-W20, 2506-20 .703" 1.000" .128" #30
(.128")
1/4 D x 110° 1/8"
2601-20, 2601-W20, 2606-20 .812" 1.375" .128" #30
(.128")
1/4 D x 110° 1/8"

2. Rivet Receptacle

Rivet Receptacle Drawing

Floating Receptacle

1. Drill holes and countersink rivet holes.

Drill and Countersink Panel Drawing
Stud Type "A"
±.010
"K"
±.005
J Drill Size Countersink Rivet
2351-20, 2351-W20, 2356-20 .468" .750" .096" #41
(.096")
3/16 D x 110° 3/32"
2501-20, 2501-W20, 2506-20 .703" 1.000" .128" #30
(.128")
1/4 D x 110° 1/8"
2601-20, 2601-W20, 2606-20 .812" 1.375" .128" #30
(.128")
1/4 D x 110° 1/8"

2. Place spacers in receptacle holes

Install Spacers Drawing

3. Rivet receptacle

Rivet Spacers and Receptacle Drawing